Size a hot wash tank against the throughput the line actually holds, not against the nameplate: real washing-line throughput runs 60-80% of nameplate. Then size the working volume from the published 30-45 minute dwell and the crusher target of 25-30 mm.
The rest follows from published figures rather than guesswork: water at 0.3-1.5 m3 per ton of flake with recirculation, 0.8-1.2 m3 for a complete washing line, float tanks from 500 to 3,000 kg/h, and a 32-58 m footprint for a full washing plus pelletizing plant.
Size the tank from the dwell
- Real throughput is 60-80% of nameplate, so size to that, not to the plate.
- The working volume comes from the published 30-45 minute dwell time.
- Water runs at 0.3-1.5 m3 per ton of flake, with recirculation on the loop.
- The crusher target of 25-30 mm decides what the tank can actually clean.

Size Against the Rate You Can Actually Hold
The first sizing mistake on a hot washing machine is sizing it against the nameplate. Real washing-line throughput runs 60–80% of nameplate, so a vessel bought for the full rated capacity spends part of its life waiting for material that never arrives at the advertised rate. Size against the bottom of that range and the tank earns its place every shift.
The second mistake is treating the wash tank as the constraint on the line. Usually it is not. The crusher upstream and the float tank downstream set the real limits, because the crusher has to deliver flake at a size the tank can actually wash and the float tank has to accept what comes out of the tank at a rate the rest of the line can take.
A sizing discussion that starts from the published capacity of each stage, in the order the material moves, produces a line that balances. A sizing discussion that starts from the largest number in any single quotation produces a line with one oversized stage and four bottlenecks, and the bottleneck is always the part that was not oversized.
Tank Volume Is a Dwell-Time Problem

The volume of a hot caustic wash vessel is set by dwell time and throughput, because that is what the vessel is for. Published conditions are 30–45 minutes per batch, so the working volume has to hold one batch of flake and its water for that period at the throughput the line will really run. The shell is larger than the working volume, because flake occupies part of it and the surface needs freeboard for agitation.
Two published ranges set the envelope. Float tanks are published at capacities from 500 to 3,000 kg/h, which brackets the throughput a hot wash stage normally serves in a commercial line. Real washing-line throughput runs 60–80% of nameplate, so a tank sized to the nameplate rate against a 30–45 minute dwell is either a tank that is never full or a tank that was overbuilt.
The float tank is a useful worked example of how this arithmetic gets published. A stainless 304 PTC500 sits at US$18,000–25,000, a PTC1000 at US$28,000–40,000 and a PTC1500 at US$45,000–65,000, FOB Shanghai, with capacities from 500 to 3,000 kg/h. The tank and the wash vessel are sized against the same tonnage, so they belong in the same quotation and the same discussion.
Turnover: How Often the Water Comes Round
A tank that is heated and dosed is also a tank that has to be emptied, refilled and topped up, and the water figures are what tell you how much of that a plant is signing for. Published figures are 0.3–1.5 m³ of water per ton of flake for a washing line with recirculation, and 0.8–1.2 m³ per ton of flake for a complete washing line.
Recirculation is what keeps that figure finite, and it is also what turns the tank into a system rather than a vessel. The circulating loop has to move the contents often enough to hold temperature and keep the flake in suspension, and that loop is where the fouling starts. A line that does not recirculate uses the whole of its water figure every time it runs, and buys the difference back in a water treatment skid.
Downstream, the water demand does not stop at the wash. The water ring pelletizer runs on a closed loop with 0.3–0.6 m³/h of make-up, an underwater pelletizer uses 0.5 m³/h, and the wastewater treatment and water recycle skid is listed at US$55,000–135,000. The hot wash is the largest single consumer in that chain, which is why the wash tank is the right place to start the water balance.
What the Washer Has to Receive and Hand On
For post-consumer material the target after crushing is 25–30 mm: small enough to wash, large enough not to be lost in the float-sink tank. That target is a washer sizing constraint in disguise. Flake much larger than 30 mm does not get its adhesive surface into the caustic, and flake much smaller disappears into the flotation stage, so a washer fed the wrong size spends caustic and gets neither clean flake nor a clean tank.
A plastic shredder is a slow, high-torque machine that tears whole bales, purgings or thick sections into 50–100 mm pieces. A plastic crusher runs faster with rotating knives and a screen, taking that output down to 25–30 mm for washing. A plastic pulverizer grinds clean rigid material into powder. The size reduction in front of the washer decides what the washer can achieve, so it is worth choosing on that basis rather than on price.
On the outlet side the flake has to leave the tank wet, alkaline and at a rate the float tank and the dryer can absorb. Flake moisture after drying falls below 1–2%, and the dryer is sized for that, so a wash stage that runs faster than the drying stage has simply moved the bottleneck one step along the line and called it a wash problem.
The Sizing Document to Ask For
Ask for the sizing in writing rather than for a capacity number. A formal quote states filtration mesh, drying method, motor power, control system and the exact scope of supply, and published prices are indicative starting prices for 2026 that are configuration-dependent. A quote that gives a headline capacity without the scope behind it cannot be compared against another quote, and the comparison is where the money is decided.
Ask what the capacity is measured over. Finished bagged pellets are quoted as an average over four hours on the pelletizing side, and the same honesty is needed on the washing side: nameplate, real throughput, batch size, batch cycle time and the working volume of the tank, so the dwell time can be checked against the published 30–45 minutes. The 12-platform comparison on this site shows how a quoted capacity is worded, and the granulator types listed on it are the ones a washed flake ends up in.
Then look at the room and the calendar. A full washing plus pelletizing plant occupies 32–58 m, a washing plant is a 45–60 day build, and freight, foundations, water treatment, spare-parts stock and installation are quoted separately from the machine price. A downstream flakes pelletizing machine rated above the washer’s real output will simply starve, and the tank will be blamed for it.
The published inputs a hot wash sizing decision rests on
Tank volume is the easiest number to get wrong, because it has to hold enough material for the batch time at the real throughput. The table shows the calculation.
| Input | Published figure | What it sizes |
|---|---|---|
| Batch dwell time | 30–45 minutes per batch | The working volume of the wash tank |
| Real throughput | 60–80% of nameplate | The rate the sizing should use |
| Water per ton of flake | 0.3–1.5 m³ with recirculation | Recirculation and make-up capacity |
| Complete washing line water | 0.8–1.2 m³ per ton of flake | The water treatment and recycle skid |
| Crusher output size | 25–30 mm | What the washer can actually clean |
| Float tank capacity | 500–3,000 kg/h | The tank the wash feeds |
| Hot wash vessel price | US$58,000–125,000 | The single stage inside the quotation |
| Plant footprint | 32–58 m | Whether the line fits the building |
Questions buyers ask about this machine
Q1: Should a hot wash tank be sized for nameplate capacity?
No. Real washing-line throughput runs 60–80% of nameplate, so a tank sized for the full rated rate is a tank that is not full in the plant. Size against the rate the line actually holds, and check the batch dwell against the published 30–45 minutes.
Q2: How much water does a hot washing line use?
Water use is quoted at 0.3–1.5 m³ per ton of flake for a washing line with recirculation, rising to 0.8–1.2 m³ per ton of flake for a complete washing line. Downstream, a closed-loop water ring needs 0.3–0.6 m³/h of make-up and an underwater pelletizer 0.5 m³/h.
Q3: Why does the crusher size matter to the wash tank?
For post-consumer material the target after crushing is 25–30 mm, small enough to wash and large enough not to be lost in the float-sink tank. Flake outside that band either keeps its adhesive in the caustic or disappears into the flotation stage, and the tank wastes its chemistry either way.
Q4: What should a sizing document contain?
The working volume of the tank, the batch size, the batch cycle time, the dwell check against 30–45 minutes, the real throughput behind the headline capacity, and the scope of supply. Published prices are configuration-dependent, so the scope of supply is the only way two quotations can be compared at all.
The companion write-ups for this machine family are: Hot Washing Machine for PET: What It Actually Removes, Hot Washing Machine: Caustic Dosing and Temperature, Hot Washing Machine vs Cold Wash: Cost per Tonne and Hot Washing Machine Acceptance and First-Week Faults.
About the author
Zhou Gong (周工) builds recycling lines at TENGLONG Plastic Machinery, a factory in Linyi, Shandong, with 18,000 m² of floor area, 30-plus staff and 820-plus lines delivered to 46 export markets. I have never seen a washing line that was too small for its dwell time; I have seen plenty that were too big for their building. The numbers in this article come from test runs and from dated published sources, not from a sales sheet.
If you want a recommendation rather than a catalogue, send the material form, the contamination level and the target output. We return a model and a price range within one working day, and the test run on 10-20 kg of your own material is free before the balance is paid.