Dehumidifying dryer sizing from published model data: hopper volume, dehumidifying airflow, dwell time and the plant equipment around the dryer.

Published dryer series run from a 12 kg hopper to 500 kg, with dehumidifying air from 40 to 400 m³/h and drying heat from 4 to 18 kW. The relationship is consistent across the range: 40 m³/h serves a 12 or 25 kg hopper, 80 m³/h a 50 kg hopper, 120 m³/h a 100 or 150 kg hopper, 200 m³/h a 200 or 300 kg hopper, and 400 m³/h a 400–500 kg hopper.

The hopper is not sized to hold a shift of material. It is sized to hold enough material to keep the dryer working while the hopper is refilled, and to give the granules enough dwell time to reach the moisture the process needs. A 500 kg/h line with a 100 kg hopper is a perfectly reasonable combination, because the hopper fills in twelve minutes.

How the published numbers fit together

  • Hopper range 12–500 kg; dehumidifying air 40–400 m³/h; drying heat 4–18 kW; regenerative heat 2.5–7.2 kW.
  • Airflow scales in steps: 40 m³/h to 25 kg, 80 to 50 kg, 120 to 150 kg, 200 to 300 kg, 400 m³/h to 500 kg.
  • Size the hopper for refill interval and dwell time, not for a shift of production.
  • The system around the dryer — the loader, the cyclone, the conveying — decides how quickly the hopper can be refilled.
3D render of a red TENGLONG machine with a feed hopper and motor beside a control cabinet and a tall vertical vessel
3D render of a red TENGLONG machine with a feed hopper and motor beside a control cabinet and a tall vertical vessel. Used here as a visual reference for the hopper and air handling around a dryer. Rendering, not a photograph of a customer plant.

The published model data, and how to read it

Dehumidifying hopper dryers are specified with three numbers — hopper capacity in kg, dehumidifying air volume in m³/h, and heating power in kW — and the published model tables make the relationships visible.

The common series runs from a 12 kg hopper with 40 m³/h of dehumidifying air and 4 kW of drying heat, through 25 kg / 40 m³/h, 50 kg / 80 m³/h, 75 kg / 80 m³/h, 100 kg / 120 m³/h, 150 kg / 120 m³/h, 200 kg / 200 m³/h, 300 kg / 200 m³/h, 400 kg / 400 m³/h and 500 kg / 400 m³/h. Drying heating power runs 4 kW at the small end and 18 kW at 500 kg; the regenerative heater power is 2.5 kW at the small end and 7.2 kW at 400–500 kg.

Two patterns are worth noticing. The dehumidifying air volume rises in steps rather than proportionally with hopper size, because the series shares blower and rotor sizes across adjacent models. And the hopper capacity rises faster than the airflow, which is why the largest hoppers in the range need longer dwell time rather than more air.

Turning your throughput into a hopper size

Rendered scene of a TENGLONG production hall with a green and white machine and people on the floor
Rendered scene of a TENGLONG production hall with a green and white machine and people on the floor. Shown here as production context. Rendering, not a photograph of a customer plant.

The sizing calculation starts from the number of hours the line runs, because a hopper is a buffer and a buffer is sized in time, not in kilograms.

The working method is: material per fill = hourly throughput × hours between refills. Then the hopper must hold that with headroom, because you cannot run a hopper to its last kilogram — the bottom cone holds material that is not yet in the drying zone.

For a line running 500 kg/h that is refilled every two hours, that is 1,000 kg of material in the system. Against the published table, that needs the 400 kg or 500 kg hopper rather than the 200 kg one, and it means the operator refills from outside the cycle rather than inside it.

For a line running 300 kg/h refilled every hour, the calculation gives 300 kg, and the 300 kg hopper with 200 m³/h is the match.

The refill interval is a production decision as much as a technical one. Refilling more often than the material needs keeps the hopper small but ties an operator to the line. The published advantage of these machines is that they can be fitted with up to four fully insulated drying bins, which decouples the refill frequency from the drying cycle entirely.

Dwell time, and the reason the biggest hopper is not always right

Dwell time is what the material actually needs, and it is measured in the hopper rather than at the mill.

The published design intent is that the drying hopper uses down-blowing dry air with a cyclone exhaust, which improves drying efficiency and reduces energy while maintaining a steady drying effect. The practical consequence is that the drying is not uniform through the hopper — the material nearest the air inlet is drier than the material at the bottom, which is why the bottom cone is the part that has to be watched.

So for a hygroscopic polymer, a larger hopper at lower airflow is not the same as a smaller hopper at higher airflow. PET flake dried in a 400 kg hopper with 400 m³/h over four hours is not the same product as PET dried in a 200 kg hopper with 200 m³/h over the same period, and the difference shows up in the batch-to-batch moisture figures.

The rule that follows: size the airflow to the polymer’s requirement and the dwell time to the refill interval, and do not let a large hopper substitute for either.

The system around the dryer

A dryer that is specified in isolation tends to be specified badly, because the four items around it decide whether it works.

First, the feeding system. A dehumidifying dryer normally combines the dehumidifying, the drying and two-stage conveying in one machine, with a feeding blower of 0.75–2.2 kW depending on model and a 1.5-inch material pipe on every model in the series. The conveying distance matters and is usually where the installation goes wrong.

Second, the insulation. The published feature list makes a point of fully insulated drying bins and of the hopper surfaces being made of dust-free mirror-finish stainless steel, suitable for optical or food-standard production. Insulating the drying zone is what makes the dew point meaningful at the bottom of the hopper.

Third, the filter. A high-density return air filter is specified to prevent contamination in conveying, and a transparent filter window is included so the condition of the filter can be monitored. A loaded return filter is one of the most common causes of a dryer that stops meeting specification.

Fourth, the dew point instrument. Without a dew point reading, the only way to know the rotor is still working is to measure the moisture of the material coming out, which is a laboratory measurement hours after the fact.

Published dehumidifying hopper dryer series

Published dryer series, so that a hopper size can be chosen against an airflow instead of guessed at.

Hopper capacity Dehumidifying air Drying heat Regenerative heat
12 kg 40 m³/h 4 kW 2.5 kW
25 kg 40 m³/h 4 kW 2.5 kW
50 kg 80 m³/h 4 kW 2.5 kW
100 kg 120 m³/h 6 kW 2.5 kW
150 kg 120 m³/h 6 kW 2.5 kW
200 kg 200 m³/h 12 kW 5.4 kW
300 kg 200 m³/h 12 kW 5.4 kW
400–500 kg 400 m³/h 18 kW 7.2 kW

Questions buyers ask about this machine

Q1: How big a dehumidifying dryer do I need for 500 kg/h?

It depends on the refill interval, not only the throughput. At 500 kg/h refilled every two hours, 1,000 kg of material has to be held in the system, which points to the 400 kg or 500 kg hopper models. At a shorter interval the smaller hoppers work. The published series spans 12 kg to 500 kg with 40 to 400 m³/h of dehumidifying air.

Q2: Does the dryer need to be bigger than my hourly throughput?

Usually yes, because the hopper is a buffer. The calculation is material per fill = hourly throughput × hours between refills, plus headroom for the bottom cone that is not yet in the drying zone. Fitting up to four fully insulated bins is one way to decouple the refill frequency from the drying cycle.

Q3: How much airflow does a dehumidifying dryer need per kg of material?

From the published series, roughly 0.8 m³/h of dehumidifying air per kg of hopper capacity at the small end and 0.8 m³/h at the large end, with the air volume stepping rather than scaling proportionally. Match airflow to the polymer’s requirement and dwell time to the refill interval — a larger hopper does not substitute for either.

Q4: What should I check when the dryer stops meeting specification?

The return air filter first, then the desiccant rotor. A high-density return filter that has loaded up will restrict the loop and raise the drying time, and a rotor past its regeneration capacity will slowly degrade the dew point. Both are consumable schedules, and both are cheaper to change than the batch of material they would otherwise spoil.

Further reading on this site: PET pelletizing line, masterbatch granulator, flakes pelletizing machine and FAQ on drying PET and PA.

The rest of this series covers the same equipment from different angles: Dehumidifying Dryer vs Hot Air Hopper for Plastic Granules, PET Crystalliser and Dehumidifying Dryer: Why Both, Dehumidifying Dryer Maintenance: Desiccant and Filters and How to Buy a Dehumidifying Dryer Without Overpaying.

About the author

Zhou Gong (周工) is a recycling machinery engineer at TENGLONG Plastic Machinery in Linyi, Shandong, where 30-plus staff work across 18,000 m² and 12 machine platforms covering 100 to 3,000 kg/h. The refill interval is the number that matters, and it is set by the loader and the cyclone, not by the dryer. I size the two together or the hopper capacity is a guess. Every figure used here has been measured on a machine or taken from a dated published source, not from a brochure.

Send the material form, the contamination level and your target output to our engineering team and you get a model and a price range within one working day. A test run on 10–20 kg of your own material is free, and if the measured output misses the agreed figure by more than 5%, the deposit is refundable.